1
0

[SCSI] bnx2i: Optimized the bnx2i_stop connection clean up procedure

For cases where the iSCSI disconnection procedure times out due to
the iSCSI daemon being slow or unresponsive, the bnx2i_stop routine
will now perform hardware cleanup via bnx2i_hw_ep_disconnect on all
active endpoints so that subsequent operations will perform properly.
Also moved the mutex locks inside ep_connect and ep_disconnect so
that proper exclusivity can resolve simultaneous calls to the
ep_disconnect routine.

v2: Removed the unnecessary read lock in the bnx2i_stop

Signed-off-by: Eddie Wai <eddie.wai@broadcom.com>
Reviewed-by: Michael Chan <mchan@broadcom.com>
Reviewed-by: Benjamin Li <benli@broadcom.com>
Acked-by: Anil Veerabhadrappa <anilgv@broadcom.com>
Reviewed-by: Mike Christie <michaelc@cs.wisc.edu>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
Eddie Wai
2010-07-01 15:34:52 -07:00
committed by James Bottomley
parent 46012e8b8d
commit 55e15c975c
3 changed files with 40 additions and 9 deletions

View File

@@ -708,7 +708,6 @@ bnx2i_find_ep_in_destroy_list(struct bnx2i_hba *hba, u32 iscsi_cid)
return ep;
}
/**
* bnx2i_ep_active_list_add - add an entry to ep active list
* @hba: pointer to adapter instance
@@ -856,9 +855,9 @@ struct bnx2i_hba *bnx2i_alloc_hba(struct cnic_dev *cnic)
mutex_init(&hba->net_dev_lock);
init_waitqueue_head(&hba->eh_wait);
if (test_bit(BNX2I_NX2_DEV_57710, &hba->cnic_dev_type))
hba->hba_shutdown_tmo = 240 * HZ;
hba->hba_shutdown_tmo = 20 * HZ;
else /* 5706/5708/5709 */
hba->hba_shutdown_tmo = 30 * HZ;
hba->hba_shutdown_tmo = 20 * HZ;
if (iscsi_host_add(shost, &hba->pcidev->dev))
goto free_dump_mem;
@@ -1700,10 +1699,11 @@ static struct iscsi_endpoint *bnx2i_ep_connect(struct Scsi_Host *shost,
if (!hba || test_bit(ADAPTER_STATE_GOING_DOWN, &hba->adapter_state)) {
rc = -EINVAL;
goto check_busy;
goto nohba;
}
cnic = hba->cnic;
mutex_lock(&hba->net_dev_lock);
ep = bnx2i_alloc_ep(hba);
if (!ep) {
rc = -ENOMEM;
@@ -1711,7 +1711,6 @@ static struct iscsi_endpoint *bnx2i_ep_connect(struct Scsi_Host *shost,
}
bnx2i_ep = ep->dd_data;
mutex_lock(&hba->net_dev_lock);
if (bnx2i_adapter_ready(hba)) {
rc = -EPERM;
goto net_if_down;
@@ -1813,8 +1812,9 @@ iscsi_cid_err:
bnx2i_free_qp_resc(hba, bnx2i_ep);
qp_resc_err:
bnx2i_free_ep(ep);
mutex_unlock(&hba->net_dev_lock);
check_busy:
mutex_unlock(&hba->net_dev_lock);
nohba:
bnx2i_unreg_dev_all();
return ERR_PTR(rc);
}