PCI: Warn if bridge window cannot be released when resizing BAR
BAR resizing calls to pci_reassign_bridge_resources(), which attempts to release any upstream bridge window to allow them to accommodate the new BAR size. The release can only be performed if there are no other child resources for the bridge window. Previously the code continued silently when other child resources were detected. Add pci_warn() to inform user that a bridge window could not be released because of child resources. As a small bridge window is often the reason why BAR resize fails, this warning will help to pinpoint to the cause. Signed-off-by: Ilpo Järvinen <ilpo.jarvinen@linux.intel.com> Signed-off-by: Bjorn Helgaas <bhelgaas@google.com> Link: https://patch.msgid.link/20250829131113.36754-15-ilpo.jarvinen@linux.intel.com
This commit is contained in:
committed by
Bjorn Helgaas
parent
3ab10f83e2
commit
85796d20a6
@@ -2555,6 +2555,12 @@ int pbus_reassign_bridge_resources(struct pci_bus *bus, struct resource *res)
|
||||
goto cleanup;
|
||||
|
||||
pci_release_resource(bridge, i);
|
||||
} else {
|
||||
const char *res_name = pci_resource_name(bridge, i);
|
||||
|
||||
pci_warn(bridge,
|
||||
"%s %pR: was not released (still contains assigned resources)\n",
|
||||
res_name, res);
|
||||
}
|
||||
|
||||
bus = bus->parent;
|
||||
|
||||
Reference in New Issue